Please click on the links below to download the relevant document for this product
FLAME RETARDANT / FIRE RESISTANT Grade 2 flush contact with multi resistors for all panels, suitable for double doors
Grade: 2
Model: A41MULTIFR
- Material: LG Chemical AF-312 ABS, Flame Retardant, High Impact, High Flow
- Flammability: UL94
- Fire Resistant
- Grade 2 Flush Tampered Quickfit Contact With Multiple Resistors
- Double door contacts
- Rectangular Plate
- Will work on shared zones / double doors / wired in series
- This is compatible with most mainstream UK control panels and includes both EOL and alarm by-pass resistor options
- It has a microswitch tamper
- Environmental Class 2
- Colour:
- White
- Note:
- Add suffix B for Brown
- Operation Gap:
- 14mm Approx
- Dimensions:
- 20mm dia body, 30mm deep
- Terminals:
- 4-Terminal Block
- Tamper:
- TACT Microswitch
- Includes resistors compatible with:
- Honeywell, Orisec, Ademco, Scantronic, Guardtec /
RISCO, Menvier, HKC, Siemens, Europlex, Guardall, DSC, Texecom, Pyronix,
Castle, PACOM and Inner Range control panels
- Honeywell, Orisec, Ademco, Scantronic, Guardtec /
- Alarm Values:
- No res, 1kr, 2k2, 4k1 (8k2), 4k7, 5k6, 6k8, 10k
- EOL Values:
- No res, 1kr, 2k2, 4k1 (8k2) 4k7, 5k6, 10k
- Just move and orientate the easily accessible coloured pcb jumpers to select-as per the instructions
- Note: this contact meets the requirements of EN50131-2-6: 2008
Please click on the links below to view the relevant videos